I have an Intex Pure Spa that throws a e95 code, meaning the water is too hot! But it will throw this code if the water is 55 F! So the water is not too hot! The heater works when the code isn't on. I thought maybe the controller was bad so I tried a buddy's controller and it did the same thing. Sometimes it does not throw the code. Does anyone know if there is a heat sensor of some kind anywhere on the pump or anything? Any help would be greatly appreciated!
Hot Tubs
A hot tub is a form of hydrotherapy used for recreational or physical therapy. It is a large tub filled with hot aerated water that often comes with various types of jets.
Hot tubs vary in shapes and sizes, most of which are only suitable for outdoor use.
Health benefits of hot tubs
There are a number of ways in which a hot tub can have a positive effect on your health.
- Soaking in a hot tub before sleeping can help insomnia sufferers to experience a deeper sleep. The hot tub will help to reset your body’s thermostat, allowing your body to fall into a natural sleep
- Hot tubs are great for relieving stress as they can increase your body’s natural endorphins. They are also great for helping headaches, muscle tension and fatigue
- Back pain is very common and can be eased using hot tub therapy. Hot tubs are particularly effective for lower back pain and often produce better results than anti inflammatory medication
- Regular sessions in a hot tub can act as a form of pain relief for arthritis sufferers. It is a safe and effective way of minimising the discomfort that arthritis can cause
Choosing a hot tub
There are two main types of hot tubs: portableand permanenthot tubs. Some people will benefit from one more than the other, so it is important to consider which one is best for you before you buy.
- Permanent Not only are permanent hot tubs the most effective, but they are also more efficient and more durable than portable tubs. A permanent hot tub will need a filter system, chemicals and a heater to function
- Portable A portable hot tub is self contained and is available in a variety of sizes. They also tend to be more aesthetically pleasing compared to permanent hot tubs
Top Products in Hot Tubs
Wondering what your spa is trying to tell you? Below is a list of common error codes from the top manufacturers of control equipment for hot tubs.
Note: The control system brand name is usually different from the hot tub brand name. You can often determine the make of the control system by looking inside the spa's equipment area. Pictured here is a Balboa® control system used in Belize Spas brand.
Disclaimer: Although we hope this information will be useful, error codes are subject to change without notice. We make no representation as to the accuracy or completeness of this data and aren't responsible for errors or omissions. Refer to your owner's manual.
Error & LCD Window Message Codes:
ACC (Applied Computer Controls)
CoLd = Temperature in the spa heater housing is below 40° F. Status of the heater element is unknown. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F.
OH = Over heat. The spa is at a temperature above 108° . Do not use spa when temperature is flashing or the OH message is displayed.
HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F.
SEoP = Sensor open or disconnected. Heater disabled but the spa is operational.
SESH = Sensor short, nonfunctional. Heater disabled but the spa is operational.
PSoC = Pressure switch open with circulating pump.
PSoL = Pressure switch open with low pump.
PSoH = Pressure switch open with high pump.
ToE = Time out error. Rare system error. Spa unusable. Contact ACC.
OH = Over heat. The spa is at a temperature above 108° . Do not use spa when temperature is flashing or the OH message is displayed.
HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F.
SEoP = Sensor open or disconnected. Heater disabled but the spa is operational.
SESH = Sensor short, nonfunctional. Heater disabled but the spa is operational.
PSoC = Pressure switch open with circulating pump.
PSoL = Pressure switch open with low pump.
PSoH = Pressure switch open with high pump.
ToE = Time out error. Rare system error. Spa unusable. Contact ACC.
Balboa
(used by Belize Spas and many other hot tubs)
pd = Power supply, unit running on battery backup
OH = Sensors reading 112-118° F.
OHH = Overheat. Spa has shut down. One sensor has detected 118° F at heater.
OHS = Overheat. Spa has shut down. One sensor has detected 110°F.
Flo = Improper flow or pressure switch malfunction
Cool = Water temp 20° below set point
ICE = Potential freeze condition has been detected
Sn1 = Hi-limit sensor malfunction
Sn3 = Temp sensor malfunction
SnA = Spa is shut down. Sensor plugged into jack A is not working.
Snb = Spa is shut down. Sensor plugged into jack B is not working.
SnS = Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message (blinking) spa is shut down.
HFL = Substantial difference between temperature sensors detected. Could indicate a flow problem.
LF = Persistent low flow problems. (Displays on the 5th occurrence of 'HFL' message with 24 hours). Heater is shut down, but other spa functions run normally.
dr = Inadequate water detected in heater.
dry = Inadequate water detected in heater. (Displays on third occurrence of 'dr' message). Spa is shut down.
Pr = When spa is first actuated, it will go into Priming Mode.
ILOC = Interlock failure - possible pump or ozone spike .
(---) =Unknown water temperature. (Displays when first powered up after refill).
Std = Spa operating in Standard Mode.
Ecn = Spa operating in Economy Mode.
SE = Spa operating in Standard-in-Economy Mode.
OH = Sensors reading 112-118° F.
OHH = Overheat. Spa has shut down. One sensor has detected 118° F at heater.
OHS = Overheat. Spa has shut down. One sensor has detected 110°F.
Flo = Improper flow or pressure switch malfunction
Cool = Water temp 20° below set point
ICE = Potential freeze condition has been detected
Sn1 = Hi-limit sensor malfunction
Sn3 = Temp sensor malfunction
SnA = Spa is shut down. Sensor plugged into jack A is not working.
Snb = Spa is shut down. Sensor plugged into jack B is not working.
SnS = Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message (blinking) spa is shut down.
HFL = Substantial difference between temperature sensors detected. Could indicate a flow problem.
LF = Persistent low flow problems. (Displays on the 5th occurrence of 'HFL' message with 24 hours). Heater is shut down, but other spa functions run normally.
dr = Inadequate water detected in heater.
dry = Inadequate water detected in heater. (Displays on third occurrence of 'dr' message). Spa is shut down.
Pr = When spa is first actuated, it will go into Priming Mode.
ILOC = Interlock failure - possible pump or ozone spike .
(---) =Unknown water temperature. (Displays when first powered up after refill).
Std = Spa operating in Standard Mode.
Ecn = Spa operating in Economy Mode.
SE = Spa operating in Standard-in-Economy Mode.
Brett Aqualine
OH = Temp exceeds 118° F
Fr = Freeze condition - temp below 40° F
FL = Pressure switch failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted flow switch
E7 = Improper electrical connection
Fr = Freeze condition - temp below 40° F
FL = Pressure switch failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted flow switch
E7 = Improper electrical connection
CTI
th1/39 = On startup indicates temperature probe problem.
th2/current temperature = On startup indicates temperature probe problem.
th3/39 = On startup indicates water temperature less than 39° F.
OH = Overheating, water over 112° F. System will restart when temp. drops.
hot = Overheating, water over 112° F. System will restart when temp. drops.
HL = High limit switch tripped.
th2/current temperature = On startup indicates temperature probe problem.
th3/39 = On startup indicates water temperature less than 39° F.
OH = Overheating, water over 112° F. System will restart when temp. drops.
hot = Overheating, water over 112° F. System will restart when temp. drops.
HL = High limit switch tripped.
Dream Maker Hot Tubs
OH = Overheat 108° F, spa is deactivated. Do not enter the water.
FL = Flow. Pressure switch is not working.
SN = Non functional high temperature sensor. Heater is deactivated.
F2 = 4 hours daily filtration
F4 = 8 hours daily filtration
F6 = 12 hours daily filtration
FC = continuous filtration
FL = Flow. Pressure switch is not working.
SN = Non functional high temperature sensor. Heater is deactivated.
F2 = 4 hours daily filtration
F4 = 8 hours daily filtration
F6 = 12 hours daily filtration
FC = continuous filtration
EasyPak
C = Celsius
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit
Fnaf 4 halloween edition download. Except here, you are not restricted by power but by time. PLAY THIS GAME!!!!The game in some ways is harder for most people to play due to its “breathing” mechanics, an interesting twist on the formula that has been with the Five Nights series since the beginning. In Five Nights at Freddy’s 4, your flashlight is not only your saviour but your downfall. A single flash of light at the wrong time can cause the animatronics to feast upon you guaranteeing a GAME OVER screen and a need to change your pants. The only mechanic keeping your robotic friends out of your room is the “Door” mechanic similar to the first game. And the suspense that there is a animontronic at the door is killing me!
Gecko
FLO = Pressure switch failure, switch open
FLC = Pressure switch failure, switch closed
Prr = Temp sensor failure
Prh = Hi-limit sensor failure
HL = Sensor measuring 119° F
FrE = Possible freeze condition detected
FLC = Pressure switch failure, switch closed
Prr = Temp sensor failure
Prh = Hi-limit sensor failure
HL = Sensor measuring 119° F
FrE = Possible freeze condition detected
Hercules
OH = Spa temp exceeds acceptable limits
FLO = Flow problem
ICE = Freeze condition detected
SN1 = Hi-limit sensor failure
SN2 = Temp sensor failure
FLO = Flow problem
ICE = Freeze condition detected
SN1 = Hi-limit sensor failure
SN2 = Temp sensor failure
Hurricane
Lazy Spa Error 08 2
PS = Flow or pressure switch failure
SH = Shorted sensor
OP = Open Sensor
LO = Temp below 60° F - freeze
HL = Temp above 118° F Serial number idm 6.32.
SH = Shorted sensor
OP = Open Sensor
LO = Temp below 60° F - freeze
HL = Temp above 118° F Serial number idm 6.32.
Hydro-Quip
C = Celsius
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit
Jacuzzi Whirlpool
OH = Overheat Protection (Heater is deactivated, pumps low speed is activated).
COOL = Spa water is more than 20° F cooler than the temperature set point.
FLO* = Flow Switch (heater is deactivated. Pump may also be deactivated).
Hold = Panel sensors have been pressed too many times in a short period of time.
HOT = Circuit Board temperature has exceeded acceptable limit.
ICE = Freeze protection. No action is necessary.
I CE2 = Freeze protection. No action is necessary.
PnL = Communication between the panel and circuit board is faulty.
---- = 'Watchdog' (spa is deactivated) A problem has been detected.
Sn1 = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated).
Sn3 = Open or shorted sensor ( heater disabled).
FLO2 = Closed or shorted flow switch on system startup
COOL = Spa water is more than 20° F cooler than the temperature set point.
FLO* = Flow Switch (heater is deactivated. Pump may also be deactivated).
Hold = Panel sensors have been pressed too many times in a short period of time.
HOT = Circuit Board temperature has exceeded acceptable limit.
ICE = Freeze protection. No action is necessary.
I CE2 = Freeze protection. No action is necessary.
PnL = Communication between the panel and circuit board is faulty.
---- = 'Watchdog' (spa is deactivated) A problem has been detected.
Sn1 = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated).
Sn3 = Open or shorted sensor ( heater disabled).
FLO2 = Closed or shorted flow switch on system startup
Pinnacle
The marked ones 123 movies. OH = Temperature has exceeded 110° F
SN = Sensor failure
FL = Flow/pressure switch stuck in closed position
SN = Sensor failure
FL = Flow/pressure switch stuck in closed position
Spa Builders
Sn1 = Nonfunctional high temperature sensor. Heater is deactivated.
Sn2 = Nonfunctional temperature sensor. Heater is deactivated.
FL1 = Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ensure pump is primed. Check for clogged filter.
FL2 = Pressure switch problem. Switch closed while pump is deactivated.
COL = Cool condition. If water temperature drops 20°F below set temperature, low speed pump and heater activates to bring temperature within 15° of set temperature.
ICE = Freeze condition. 55°F detected. Low speed pump and heater will activate until spa reaches 65°F.
OH = High temperature condition, has reached 110°F. Do not enter the spa. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature.
--- = 'Watchdog'. Water temperature has reached 118°F. Entire system is disabled. Contact qualified service technician.
Sn2 = Nonfunctional temperature sensor. Heater is deactivated.
FL1 = Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ensure pump is primed. Check for clogged filter.
FL2 = Pressure switch problem. Switch closed while pump is deactivated.
COL = Cool condition. If water temperature drops 20°F below set temperature, low speed pump and heater activates to bring temperature within 15° of set temperature.
ICE = Freeze condition. 55°F detected. Low speed pump and heater will activate until spa reaches 65°F.
OH = High temperature condition, has reached 110°F. Do not enter the spa. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature.
--- = 'Watchdog'. Water temperature has reached 118°F. Entire system is disabled. Contact qualified service technician.
Sundance Spas
ILOC = Interlock failure - possible pump or ozone spike
FLO = Pressure switch malfunction or Flow switch malfunction (system specific)
Hold = Panel buttons pressed to many times to quickly
HOT = PCB temperature above acceptable limit - air blower on
ICE = Potential freeze condition
Pnl = Communication between PCB and panel interrupted
Sn1 = Hi-limit sensor failure
Sn3 = Temp sensor failure
---- = 'Watchdog' (spa is deactivated) A problem has been detected
FLO = Pressure switch malfunction or Flow switch malfunction (system specific)
Hold = Panel buttons pressed to many times to quickly
HOT = PCB temperature above acceptable limit - air blower on
ICE = Potential freeze condition
Pnl = Communication between PCB and panel interrupted
Sn1 = Hi-limit sensor failure
Sn3 = Temp sensor failure
---- = 'Watchdog' (spa is deactivated) A problem has been detected
Vita Spas
HiLi = Water temp over acceptable limit
BJ2P = Pump/Blower purge - normal condition
FP = Freeze protect-temp under acceptable condition
SS=0; SS=S; LS=O; LS=S = Multiple causes; open sensors, bad connection to panel, improper voltage, etc.
BJ2P = Pump/Blower purge - normal condition
FP = Freeze protect-temp under acceptable condition
SS=0; SS=S; LS=O; LS=S = Multiple causes; open sensors, bad connection to panel, improper voltage, etc.
Eo2 Error Code Lazy Spa
'Very pleased with the ease of installation and all the diagnostic features that other spa packs did not even have. Like the name says, it was quite easy to install.'James Hirsch
Buffalo, NY
Buffalo, NY
Lay Z Spa Paris Error 08
- (70)Total Ratings 70,100% agree - Would recommend
- Intex PureSpa Cup Holder, 2 Standard Size Beverage Containers(51)Total Ratings 51,100% agree - Would recommend
- Bulletproof Kit™ fits Watkins IQ2020 Heater Relay Board 73355,74618,76071. 77119(39)Total Ratings 39,97% agree - Would recommend
- (29)Total Ratings 29,100% agree - Would recommend
- 'Pleatco PWK30 Replacement Cartridge for Watkins Hot Spring Spas, 1 Cartridge'(26)Total Ratings 26,100% agree - Would recommend
- Frog Ease SmartChlor Floating Chlorine & Mineral Sanitizing System Pool Tub Spa(17)Total Ratings 17,100% agree - Would recommend
- Coleman SaluSpa 6 Person Inflatable Outdoor Spa Jacuzzi Bubble Massage Hot Tub(13)Total Ratings 13,100% agree - Would recommend
- Inflatable Hot Tub Portable 4 Person Heated Spa Bestway Miami Indoor Outdoor(135)Total Ratings 135,89% agree - Would recommend$282.96 Used